This service listing covers crystal replacement for the GE 4C-RS convex ultrasound probe. When a 4C-RS transducer starts to lose sensitivity, shows vertical banding, or develops dark stripes across the abdominal image, the root cause is almost always a group of failed piezoelectric elements inside the acoustic stack. Instead of asking clinical departments to purchase a new probe at full OEM cost, our workshop opens the probe head, removes the damaged crystal rows, and rebuilds the array with graded replacement elements matched to the original pitch and impedance. Every unit returns to service with a documented element map, a fresh acoustic lens, and a pressure-tested seal.
| Parameter | Specification |
|---|---|
| Compatible Probe Model | GE 4C-RS convex (also 3C-RS, 4C-RC, C1-5-D on request) |
| Probe Type | Curved array, abdominal and obstetrics |
| Array Elements | 128 elements, crystal replacement in single element or block groups |
| Nominal Frequency | 2.5 to 5.0 MHz, crystal thickness matched to the original center frequency |
| Element Pitch | Reproduction of original pitch within 0.01 mm tolerance |
| Replacement Crystal | Medical grade PZT-5H equivalent, capacitance sorted in 5 percent bands |
| Acoustic Lens | New molded lens, RTV bonded and vacuum degassed |
| Sealing | IPX7 equivalent immersion test, 30 minutes at 1 m, performed on every unit |
| Verification | Element map, sensitivity spread, resolution and penetration scan on a GE compatible system |
| Turnaround | 5 to 7 working days for standard faults, 3 days expedited |
| Warranty | 12 months on replaced crystals and lens bond |
Crystal replacement is the right entry point for radiology and obstetrics departments running GE Logiq and Vivid class systems where the 4C-RS probe still delivers good penetration but has developed stripes or a weak sector. It also suits independent service organizations and used equipment dealers who buy probe cores with known element failures, rebuild the array, and resell the unit with a documented test report. Because the housing, cable, and connector are reused, the cost of the repair typically lands far below a replacement probe, and the clinical workflow only needs a loaner for about one week. Veterinary clinics and point-of-care users with a single abdominal probe are also frequent customers, since a dead element in a convex array is far more disruptive than in a probe used occasionally.
Every rebuilt probe is packed in a shock-absorbing foam cradle inside an export-grade carton, together with the element map printout and the immersion test record. Before dispatch, the unit runs a penetration and resolution scan on a compatible GE system, and the image set is archived against the probe serial number. Crystalline cleaning, low-temperature cure, and controlled-humidity assembly are used throughout the crystal bonding stage, which is where most independent rebuilds fail. If a replaced element drifts outside tolerance during the warranty period, the probe is taken back, re-mapped, and re-bonded at no additional charge.