products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
GE Ultrasound Probe Repair
Created with Pixso.

192 Element Array Ultrasound Probe Repair with 5-7 Day Turnaround and 12 Month Warranty for Piezoelectric Crystal Replacement

192 Element Array Ultrasound Probe Repair with 5-7 Day Turnaround and 12 Month Warranty for Piezoelectric Crystal Replacement

Brand Name: MYPRO
Model Number: GE 9L-D Crystal Replacement
MOQ: 1 Piece
Price: Negotiable
Payment Terms: T/T,Western Union,PayPal
Supply Ability: 200 Pieces per Month
Detail Information
Place of Origin:
Guangdong, China
Certification:
ISO 9001:2015
Service Type:
Piezoelectric Crystal Replacement And Array Rebuild
Compatible Model:
GE 9L-D
Probe Type:
Linear Array
Array Elements:
192
Frequency Range:
4.0-10.0 MHz
Replacement Crystal:
PZT-5H Equivalent, Lapped And Poled
Matching Layer:
Two Stage Acoustic Matching Layer
Sealing Test:
Immersion 30 Min At 1 M
Turnaround:
5-7 Working Days
Warranty:
12 Months
Packaging Details:
420mm*270mm*100mm for 1 probe
Supply Ability:
200 Pieces per Month
Highlight:

piezoelectric crystal replacement

,

9L-D linear array rebuild

,

probe acoustic stack repair

Product Description
Overview

Piezoelectric crystal replacement for the GE 9L-D linear probe is a repair path built for vascular, musculoskeletal, and small parts imaging, where a single dead element shows up immediately as a vertical dropout. The 9L-D array is dense and thin, so a failed crystal row cannot simply be bridged or bypassed. The array has to be opened, the damaged elements removed, and new crystals lapped to the exact thickness that restores the original center frequency. Our workshop performs that operation in house, then re-laminates the matching layer and refits a new lens so the probe returns to clinical duty with a uniform element response instead of a patchwork image.

Key Features
  • Precision Crystal Lapping: Replacement PZT plates are lapped and poled to the thickness required by the 9L-D center frequency, which keeps the axial resolution consistent across the rebuilt section.
  • Element-by-Element Fault Isolation: A kerf-level scan identifies open, shorted, and weak elements separately, so only the genuinely failed crystals are replaced and the rest of the array keeps its original performance history.
  • High-Density Array Handling: Thin linear arrays are easy to destroy during rework, so bonding, curing, and dicing are done under magnification with temperature-controlled fixtures rather than hand-applied adhesive.
  • Matching Layer and Lens Rebuild: The acoustic window is rebuilt with a new lens and a re-bonded matching layer, removing the air gaps that cause ringing and reduced near-field resolution.
  • Documented Acceptance Test: Each probe ships with a sensitivity profile, a dead element count, and a wire phantom image set captured on a GE-compatible scanner.
  • Service Program Friendly: Batch pricing is available for fleet owners and refurbishers who send several linear probes per quarter and need predictable turnaround.
Technical Specifications
Parameter Specification
Compatible Probe Model GE 9L-D linear (also 8L-RS, 11L-D, 12L-RS on request)
Probe Type Linear array, vascular and small parts
Array Elements 192 elements, crystal replacement in single element or continuous block groups
Nominal Frequency 4.0 to 10.0 MHz, crystal thickness matched to original center frequency
Element Pitch Original pitch reproduced within 0.01 mm tolerance
Replacement Crystal Medical grade PZT-5H equivalent, capacitance sorted in 5 percent bands
Matching Layer Two-stage acoustic matching layer, re-bonded and vacuum degassed
Acoustic Lens New molded lens, RTV bonded, cure controlled at low temperature
Sealing Immersion test 30 minutes at 1 m on every finished unit
Verification Element map, sensitivity spread, wire phantom resolution set
Turnaround 5 to 7 working days for standard faults, 3 days expedited
Warranty 12 months on replaced crystals and lens bond
Applications

The 9L-D is used daily for carotid and peripheral vascular studies, thyroid and breast work, and musculoskeletal injections, so a striped image is a scheduling problem rather than a cosmetic one. Crystal replacement keeps the original connector, cable, and housing in service, which matters for departments that have already validated the 9L-D preset on their GE system and do not want to re-qualify a new probe model. Refurbishment companies use the same service to convert cores with known element faults into sellable inventory, and mobile imaging providers rely on it to keep a small probe pool in rotation without buying new transducers.

When the whole array has failed rather than a localized group, we report that honestly and recommend replacement instead of charging for a rebuild that cannot meet specification.

Packaging & Quality Assurance

Finished probes travel in a foam-cradled export carton with the element map, immersion test record, and wire phantom images enclosed. Rework is performed in a humidity-controlled area because moisture ingress during crystal bonding is the main cause of premature element failure in rebuilt linear arrays. Each replacement crystal is checked for capacitance and pulse-echo response before bonding and again after cure, and any element that drifts outside the acceptance band is removed and replaced rather than accepted with a note. Warranty covers crystal and lens bond defects for twelve months, and returned units are re-mapped and re-bonded without additional labour charges.